Glossary: the vocabulary of sharing medical imaging
The most common terms, from DICOM and Hounsfield units to the data-processing agreement — short and clear, with links to the detailed articles.
Terms are listed alphabetically; each one can be linked to directly.
- CBCT (cone-beam CT)
- 3D X-ray imaging used in dentistry and ENT. A study is typically 200–800 MB; its grey values are not calibrated Hounsfield units. More →
- Controller
- The party that determines the purposes and means of processing personal data and is accountable for it — for imaging studies typically the practice, imaging centre or hospital (GDPR Art. 4(7)). More →
- CT (computed tomography)
- X-ray cross-sectional imaging that measures tissue attenuation in Hounsfield units. A study consists of several series and reconstructions. More →
- Curved planar reformation (CPR)
- An image “straightened out” from the volume along a drawn curve — in dentistry the dental arch; it gives a panoramic-like overview, but its accuracy depends on the curve and the slab thickness. More →
- Data-processing agreement (DPA)
- The written contract between controller and processor required by GDPR Article 28: subject of processing, security measures, sub-processors and the fate of the data at the end of the service. More →
- DICOM
- The international standard of diagnostic imaging (Digital Imaging and Communications in Medicine). Besides the pixels, a DICOM file contains a header with patient, study and acquisition data. More →
- DICOMDIR
- The table-of-contents file of patient CDs, listing the patients, studies, series and image files on the disc. More →
- Hounsfield unit (HU)
- The CT attenuation scale: water is 0, air −1000, cortical bone around +1000. More →
- Lossless compression
- Compression (e.g. JPEG-LS, JPEG 2000 lossless, RLE) from which the original pixels can be restored exactly; the expected standard for diagnostic data. More →
- MIP (maximum intensity projection)
- Display of the highest-intensity voxels within a thicker slab; useful for following vessels, contrast-filled structures or root canals. More →
- Modality
- The acquisition type in the DICOM header: e.g. CT, MR, DX (digital X-ray), US (ultrasound), XA (angiography). More →
- MPR (multiplanar reconstruction)
- Computing any plane from a 3D volume — typically axial, coronal and sagittal planes at once. More →
- MR (magnetic resonance imaging)
- Imaging without ionising radiation; a study typically has 10–30 series (sequences, planes, contrast phases). More →
- Multi-frame DICOM
- A DICOM file holding the whole volume (every slice) in one file — common in CBCT exports. More →
- PACS
- Picture Archiving and Communication System: the image archiving and distribution system of hospitals and imaging centres. More →
- Passkey
- A password-less sign-in key bound to a phone or computer (unlocked with fingerprint, face recognition or PIN); resistant to phishing.
- Personal data breach
- A breach of the security of personal data, e.g. a lost storage device or a study sent to the wrong recipient. If it involves a risk, it must be reported to the supervisory authority within 72 hours (GDPR Art. 33). More →
- Processor
- A party processing personal data on behalf of and on the instructions of the controller — e.g. a storage or image-sharing provider (GDPR Art. 4(8)). More →
- Series
- A group of images in a study acquired with the same settings — e.g. the soft-tissue and bone reconstructions of a CT, or one sequence of an MR. More →
- Slice series
- DICOM storage in which every slice is a separate file, often without an extension — the norm for CT and MR. More →
- Windowing (window level / width)
- Choosing the displayed grey-level range by a centre and a width. The same CT slice looks different in a brain window (40/80 HU) and a bone window (500/2000 HU). More →